Technical Data
3A0869H 79

Technical Data

ProMix 2KE, Meter-Based Systems
US Metric
Maximum fluid working pressure See Models, page 3.
Maximum working air pressure 100 psi 0.7 MPa, 7 bar
Air supply 75 to 100 psi 0.5 to 0.7 MPa, 5.2 to 7 bar
Air filter inlet size 3/8 npt(f)
Air filtration for air logic (Graco-supplied) 5 micron (minimum) filtration required; clean and dry air
Air filtration for atomizing air (user-supplied) 30 micron (minimum) filtration required; clean and dry air
Mixing ratio range 0.1:1 to 30:1
On-ratio accuracy up to ± 1%, user selectable
Fluid inlet sizes 1/4 npt(f)
Fluid outlet size (static mixer) 1/4 npt(f)
External power supply requirements 85 - 250 Vac, 50/60 Hz, 2 amps maximum draw
15 amp maximum circuit breaker required
8 to 14 AWG power supply wire gauge
Operating temperature range 41° to 122°F 5° to 50°C
Approximate weight 200 lb 91 kg
Environmental conditions rating indoor use, pollution degree (2), installation category II
Fluids handled one or two component:
solvent and waterborne paints
• polyurethanes
• epoxies
acid catalyzed varnishes
Fluid flow rate range
G3000, G250 Meter 0.02 to 1.00 gal/min 75 to 3800 cc/min
G3000HR, G250HR Meter 0.01 to 0.50 gal/min 38 to 1900 cc/min
Coriolis Meter 0.005 to 1.00 gal/min 20 to 3800 cc/min
S3000 Solvent Meter (accessory) 0.01 to 0.50 gal/min 38 to 1900 cc/min
Noise level
Sound pressure level below 70 dBA
Sound power level Below 85 dBA
Materials of construction
Wetted materials on all models 303, 304 SST; Tungsten carbide (with nickel binder);
perfluoroelastomer; PTFE