Setup Mode Details
3A0869H 49
Calibration 1 and 2 (Screens 22
and 23)
NOTE: See Meter Calibration, page 32, for detailed
instructions.
Calibration 1 (Screen 22) displays if is selected on
Setup Home (Screen 17). This screen displays the k
factor (cc/pulse) for Meter A with fluid A1 (A2 and A3, if
present) and Meter B. The system starts at the default
factor(s) for the meters. Factor values update automati-
cally as needed based on calibration results from Cali-
bration 2 (Screen 23). Factor values also can be set on
this screen, from 0 to 0.873 cc/pulse.
Press to display Calibration 2 (Screen 23). This
screen allows the user to perform a calibration. It dis-
plays Meter A (with fluid A1, A2, and A3) and Meter B
k-factors, the target dispense volume, the actual dis-
pense volume (settable from 0 to 9999 cc), and the
material to dispense.
• Press to highlight the meter you wish to cali-
brate. Press . An X displays in the box.
• Press to start the calibration on the checked
meter (A with fluid A1, A2, or A3, or B). Press
to cancel the calibration.
• Press to highlight the actual dispense vol-
ume field. Press to set the volume (from 0 to
9999 cc). Press to move between digits.
Press to change a digit. Press when
field is correct.
• Use to toggle between Calibration 1
(Screen 22) and Calibration 2 (Screen 23).
Troubleshooting (Screens
35-37)
Screens for testing system controls can be accessed by
setting the password to 9909. See Configure 3 (Screen
20), page 46, to set or change the password.
After setting the password to 9909, press to exit
Setup. Press to reenter Setup. Setup Home
(Screen 17) displays, with troubleshooting screen
options.
F
IG
. 46. Calibration 1 (Screen 22)
F
IG
. 47. Calibration 2 (Screen 23)
Meter k
factors
Home
Meter B
k factor
Meter A
k factors
Active
Recipe
Target
dispense
volume
Actual
dispense
volume
Start Meter A
or Meter B
Calibration
Home
Cancel Meter
Calibration
Selected
material
F
IG
. 48. Setup Home with Troubleshooting
Troubleshooting
screen options
appear here.