Display Module
3A0869H 23

Display Module

Display

Shows graphical and text information related to setup
and spray operations. The screen backlight is factory
set to remain on. The user may set a number of minutes
the screen can be inactive before the backlight dims.
See Configure 3 (Screen 20), page 46. Press any key
to restore.
NOTE: The Display Module and bracket can be
removed from the cover of the electrical box and
mounted remotely, if preferred.
Keys are used to input numerical data, enter setup
screens, navigate within a screen, scroll through
screens, and select setup values.
F
IG
. 13. Display Module
Soft keys
LCD Display
Navigation keys
Error Reset
Key
Navigation Keys
Enter key
Setup Key
Standby Key
Potlife state Active recipe
Operation mode; see
page 24 for key
ti16319a
Screen number Error code
Ratio
Potlife timers
Flow rate
NOTICE
To prevent damage to the soft key buttons, do not
press the buttons with sharp objects such as pens,
plastic cards, or fingernails.
Key Function

Setup:

Press to enter or exit
Setup mode.

Enter:

Press to choose a field to
update, to make a selection, or
to save a selection or value.

Left/Right Arrows:

Use to move
from screen to screen.

Up/Down Arrows:

Use to move
among fields on a screen, items
on a dropdown menu, or digits
in a settable field.

Error Reset:

Use to clear alarm
so cause can be fixed. Also use
to cancel a data entry field.

Standby:

Stops the current
operation and puts the system
into standby.

Soft keys:

Press to select the
specific screen or operation
shown on the display directly
above each key

.