Component Identification
Key:
RMain Disconnect Switch - Controls power to heating circuits. I
SMain Air Filter - Filters system air supply.
TResin (B) Pressure Gauge - Displays pressure in resin proportioning system (B side).
UResin (B) - Inlet Supply Valve
VResin (B) Fluid
WISO (A) Pressure Gauge - Displays pressure in isocyanate proportioning system (A side).
XISO (A) - Inlet Supply Valve
YISO (A) Fluid
ZISO (A) Pump Lube System - Behind Proportioner shroud. (A side only)
AAISO (A) - Packing Nut and Lube Cup - (A side only)
AB *Primary Heater Thermocouples - Senses temperature of primary heater and inputs that information.
AC FTS Jumper Harness - Carries electrical signal from FTS sensor in isocyanate hose to hose temperature controller.
AD Primary Heaters - Heats material to required dispensing temperature.
AE ISO (A) - (Isocyanate) Proportioning Pump - Draws in and dispenses a fixed volume of isocyanate to gun.
AF Resin (B) Proportioning Pump - Draws in and dispenses a fixed volume of resin to gun.
AG
power to heated hoses.
AH *Primary Heater
AI Resin (B) Pump Wet Cup - Access for daily wet cup refill.
DDMain Air Inlet Ball Valve - (1/2 NPT female fitting)
FFISO (A) Inlet - Fitting (3/4 swivel fitting)
GGResin (B) Inlet - Fitting (3/4 swivel fitting)
12 | 3A1569B |