Park

Park

Park the pumps at the end of the day to cycle propor- tioner pumps to home position, submerging displace- ment rod.

1. Open the park valve.

Open

Close

2.Trigger the gun until pumps stops at the bottom and relieves pressure.

3.Close the air motor shutoff valve.

4.Close the park valve.

Pressure Relief

Procedure

The Fusion AP gun is shown.

1.Turn off feed pumps and agitator if used.

2.Park component A pump. Follow Park; see page 26.

3.Close the air inlet valve.

4.Trigger spray gun until gauges read zero.

5. Engage gun piston safety lock.

ti2409a

6. Close gun fluid inlet valves A and B.

ti2421a

7. Close pump inlet supply valves.

ti17716a

Shutdown

1. Turn main heater power OFF

.

2.Follow Park; see page 26.

3.Check and fill wet-cups (AK, Z).

4.Follow gun shutdown procedure. See gun manual.

26

3A1569B

Page 26
Image 26
Graco A-25 important safety instructions Park, Pressure Relief Procedure, Shutdown, Open Close