Setup

5.Connect cables (SS). Connect electrical connectors (NN). Be sure cables have slack when hose bends. Wrap cable and electrical connections with electrical tape.

SS

NN

ti17787a

Close Gun Fluid Inlet Valves A and B

Connect Whip Hose to Gun or Gun Fluid Manifold

For Probler P2 guns: Connect hoses to inlet valves.

For Fusion guns: Connect hoses to inlet manifold. Do not connect manifold to gun.

1.Overlap A and B component hoses and assemble to gun or gun manifold fittings as shown.

2.Tighten fittings to A and B component hoses. Ensure hose remains flat after fittings are tightened. Loosen and retighten fittings as necessary to elimi- nate any torque on hoses.

Fusion AP Gun shown.

ti12158a

Fusion AP Gun shown.

ti2411a

20

3A1569B

Page 20
Image 20
Graco A-25 important safety instructions Fusion AP Gun shown