Install Air Fittings

Install Air Fittings

1.Install the supplied 1/4 in. tube fitting into the cylinder (CYL) air port.

2.Install 3/8 in. tube fittings into the atomiza- tion (ATOM) air port and the fan (FAN) air port.

CYL

ATOM

FAN

ti8211a

FIG. 2: Air Fittings

Installation

Ground Air Compressors and Hydraulic Power Supplies

Ground the air compressors and hydraulic power supplies according to the manufacturer recommendations.

Ground Spray Gun

Ground the spray gun by mounting the mani- fold to a properly grounded reciprocator, robot, or stationary mount. Check the electrical resis- tance between the manifold and a true earth ground. The resistance must be less than 1 megohm.

Ground Fluid Supply Container

Ground the fluid supply container according to local code.

Ground Object Being Sprayed

Ground the object that is being sprayed according to local code.

Ground System

The following grounding instructions are mini- mum requirements for a system. Your system may include other equipment or objects that must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true earth ground.

Ground Pump/Fluid Supply

Ground the pump by connecting a ground wire and clamp between the fluid supply and a true earth ground as instructed in your separate pump instruction manual.

Ground Solvent Pails

Ground all solvent pails that are used when flushing according to local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.