Convertible Electric Motor Runs -

No AC Output to Sprayer Control Board

Troubleshooting Procedure

(see following page for actual steps):

Troubleshooting

See step 1.

Is there over 10-20 AC volts?

YES

See the sprayer control board trou- bleshooting in this manual.

See step 2.

NO Is there continuity?

YES

See step 3.

Is there continuity?

YES

See step 4.

Is there over 100

AC volts?

Repair or replace

NO the power cord.

Repair or replace

NO the power cord.

 

Repair or replace

NO

wire splice(s) on

the power cord

 

 

wires.

YES

See step 5. Is there over 10-20 AC volts.

YES

Replace cord jack.

NO Replace transformer.

332919C

29

Page 29
Image 29
Graco 16W987, ti23055a, 16W884, 16W881, 16W867, 16W887, 16W984, 16W873, 16W871, 16W882 See step Is there over 10-20 AC volts?