Page 19
Image 19

Cleaning InstaCleanFluid Filter (XR models

only)

The InstaClean Fluid Filter prevents particles from entering paint hose. After each use, remove and clean it to insure peak perfor- mance.

1. Turn power switch OFF.

 

WLD

2. Disconnect

 

airless spray

InstaClean filter

hose from

sprayer and

Then, unscrew

remove

outlet fitting

InstaClean

First,

Fluid Filter.

unscrew hose

 

TIA

3.Check InstaClean Fluid Filter for debris. If needed, clean filter with water and a soft brush.

4.Install InstaClean Fluid Filter.

Install open end of InstaClean filter in outlet fitting, then screw outlet fitting into sprayer outlet.

TIA

outlet fitting

Shutdown and Cleaning

WLD

5.Tighten outlet fitting and reconnect hose to sprayer.

Gun Fluid Filter

Clean gun fluid filter with compatible solvent and a brush every time you flush the system. Replace gun filter when damaged.