| Troubleshooting |
|
|
|
Problem | Cause | Solution |
|
|
|
|
|
|
Pump does not prime. | Turn | |
| SPRAY position. | PRIME/DRAIN position (pointing |
|
| down). |
|
|
|
| Inlet screen (L) is clogged or suction | Clean debris off inlet screen and |
| tube (G) is not immersed. | make sure suction tube is at bottom |
|
| of paint pail. |
|
|
|
| Inlet valve check ball is stuck. | Remove suction tube and place a |
|
| pencil into the inlet section to dis- |
|
| lodge the ball, allowing pump to |
|
| prime properly. OR Power Flush |
|
| sprayer, page 17. |
|
|
|
Pump does not prime. | Outlet valve check ball is stuck. | dx Sprayer: Remove hose from |
|
| sprayer. Unscrew outlet valve to |
|
| remove assembly with a screwdriver. |
|
| Screw the valve back on the pump. |
|
| XR Sprayers: Use a screw driver to |
|
| open the |
|
| Unscrew outlet valve with a 3/4 in. |
|
| wrench. Remove and clean assem- |
|
| bly. |
|
|
|
| Suction tube is leaking. | Tighten suction tube connection (K). |
|
| Inspect for cracks or vacuum leaks. |
|
|
|
| Clean/replace drain tube as neces- | |
|
| sary. Take sprayer to Graco/mag- |
|
| num authorized service center if |
|
| valve is plugged. |
|
|
|
Spray gun stopped spraying. | Spray tip is clogged. | Unclog spray tip, page 12. |
|
|
|
Pump cycles but does not build up | Pump is not primed. | Prime pump. |
pressure. |
|
|
|
|
|
Pump cycles but does not build up | Inlet screen (L) is clogged or suction | Clean debris off inlet screen and |
pressure. | tube (G) is not immersed. | make sure suction tube is at bottom |
|
| of paint pail. |
|
|
|
| Paint pail is empty. | Refill paint pail. Reprime sprayer. |
|
|
|
Pump cycles but does not build up | Suction tube is leaking. | Tighten suction tube connection (K). |
pressure. |
| Inspect for cracks or vacuum leaks. If |
|
| cracked or damaged, replace suction |
|
| tube. |
|
|
|
| Pump check valves are dirty or dam- | Clean or replace check valves. Read |
| aged. (Usually only one valve). | Pump Check Valves, page 11. |
|
|
|
| Take sprayer to Graco/magnum | |
| or obstructed with debris. | authorized service center. |
|
|
|
| Pump check ball is stuck. | Read Pump does not prime section |
|
| in Troubleshooting, page 23 |
|
|
|
309225W | 23 |