| Troubleshooting | |
|
|
| |
Problem | Cause | Solution | |
|
|
| |
|
|
| |
Motor is hot and runs intermittently. | Vent holes in enclosure are plugged | Keep vent holes clear of | |
This is NOT a thermal overload con- | or sprayer is covered. | obstructions and overspray and | |
dition. Motor automatically shuts off |
| keep sprayer open to air. | |
due to excessive heat. Damage can |
|
| |
Extension cord is too long or not a | Replace extension cord. Read | ||
occur if cause is not corrected. | |||
heavy enough gauge. | Grounding and Electrical | ||
Thermal Overload, page 5. | |||
| Requirements, page 5. | ||
|
| ||
|
|
| |
| Unregulated electrical generator | Use electrical generator with a | |
| being used has excessive voltage. | proper voltage regulator. Sprayer | |
|
| requires 120VAC, 60 Hz, | |
|
| ||
|
|
| |
| Sprayer was operated at high | Decrease pressure setting or | |
| pressure with very small tip which | increase tip size. | |
| causes frequent motor starts and |
| |
| excessive heat build up. |
| |
|
|
| |
Building circuit breaker opens after | Too many appliances are plugged in | Free up circuit (unplug things), or | |
sprayer operates for 5 to 10 minutes. | on same circuit. | use a less busy circuit. | |
|
|
| |
| Sprayer electrical cord is damaged. | Check broken insulation or wires. | |
|
| Replace electrical cord if | |
|
| damaged. | |
|
|
| |
| Extension cord is damaged or too | • Plug in something that you | |
| long or not a heavy enough gauge. | know is working to test exten- | |
|
| sion cord. | |
|
| • Replace extension cord. | |
|
|
| |
Fan pattern varies dramatically while | Pressure control switch is worn and | Take sprayer to Graco/magnum | |
spraying. | causing excessive pressure variation. | authorized service center. | |
OR |
|
| |
Sprayer does not turn on promptly |
|
| |
when resuming spraying. |
|
| |
|
|
| |
Cannot trigger spray gun. | Spray gun trigger safety is locked. | Rotate trigger safety lever to | |
|
| unlock SAFETY, page 8. | |
|
|
| |
Spray comes out of spray gun in two | Reversible spray tip is in UNCLOG | Rotate | |
thick streams. | position. | spray tip so it points forward in | |
|
| SPRAY position. | |
|
|
| |
Paint is coming out of pressure | Pressure control switch is worn. | Take sprayer to Graco/magnum | |
control switch. |
| authorized service center. | |
|
|
| |
System is over pressurizing. | Take sprayer to Graco/magnum | ||
automatically relieving pressure |
| authorized service center. | |
through drain tube. |
|
| |
|
|
| |
Paint leaks down outside of pump. | Pump packings are worn. | Replace pump packings. | |
|
|
|
309225W | 25 |