Installation

Grounding and Electric Requirements

Sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for electrical current due to static build up or in the event of a short circuit.

The 120 Vac spray- ers require a 120 Vac, 60 Hz, 15A cir- cuit with a ground-

Installation

Fluid supply container: follow local code.

Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface such as con- crete. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.

Grounding the metal pail: connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe.

Maintaining ground- ing continuity when flushing or relieving pressure: hold metal part of the spray gun

firmly to the side of a

ing receptacle. The

230 Vac ModelWLD

247328 requires

grounded metal pail, then trigger the gun.

TIA

230 Vac, 50 Hz, 10A with a grounding recepta- cle, Never use an outlet that is not grounded or an adapter.

Do not use the sprayer if the electrical cord has a damaged ground prong.

Only use an extension cord with an undamaged 3-prong

plug. Recommended exten-

WLD

sion cords for use with this sprayer:

25 ft (7.6 m) 18 AWG (1.0 mm2)

50 ft (15.2 m) 16 AWG (1.0 mm2)

100 ft (30.5 m) 14 AWG (1.5 mm2)

150 ft (45.7 m) 12 AWG (2.5 mm2)

Spray gun: ground through connection to a properly grounded fluid hose and pump.

Smaller gauge or longer extension cords may reduce sprayer performance.

Thermal Overload

Motor has a thermal overload switch to shut itself down if overheated.

To reduce risk of injury from motor starting unex- pectedly when it cools, always turn power switch OFF if motor shuts down.

309225W

5

Page 5
Image 5