Installation

c.Connect the end of the tube (T) to the pump fluid outlet fitting (Z).

CAUTION

The Graco warranty is void if the spray gun is con- nected to a non-Graco voltage isolation system or if the gun is operated above 60 kV.

CAUTION

Factory Mutual approval is valid only when this gun is used with Factory Mutual approved voltage isolation systems.

245895 Agitator Kit

To add an agitator to the Graco isolation system, order Part No. 245895. See page 67 for the kit parts list.

1.Discharge the system voltage (page 20).

2.Relieve the pressure (page 20).

3.Open the isolated enclosure door.

4.Remove the back of the control box (258).

5.Remove tube (A2) from elbow (282) at the air mani- fold; see the tubing diagram on page 64. Install the Y fitting (402) into the elbow. Install tubes (A2) and (407) into the Y fitting. See FIG. 11.. Route the agita- tor tube (407) into the cabinet.

6.Replace the back of the control box (258).

7.Assemble the other parts of the kit as shown. Secure the agitator with the setscrew (408).

8.Return the system to service.

Connect to elbow (282)

402 inside control box (258)

407

401

406

Install tube A2 here

403

408

404

406 (Ref)

TI2137A

Fig. 11. 245895 Agitator Kit

14

309293K

Page 14
Image 14
Graco Inc 244582, 309293K, 244581 important safety instructions Agitator Kit