Operation

Operation

Operating Checklist

Check the following list daily, before starting to operate the system, to help ensure you of safe, efficient operation.

All operators are properly trained to safely operate an electrostatic waterborne air spray system as instructed in this manual.

All operators are trained in the Pressure

Relief Procedure on page 20.

The electrostatics are turned off and properly grounded according to the.Fluid Voltage Dis- charge and Grounding Procedure on page 20 before any person enters the safety enclo- sure, before cleaning, and before performing any maintenance or repair.

The system is thoroughly grounded and the operator and all persons entering the spray area are properly grounded. See Grounding on page 17.

Fluid Hose is in good condition with no cuts or abrasions of the PTFE layer. Replace hose if damaged.

Ventilation fans are operating properly.

Workpiece hangers are clean and grounded.

All debris, including flammable fluids and rags, is removed from the spray area.

Only fluids with a flash point above 140°F (60°C) and a maximum organic solvent con- centration of 20%, by weight, may be in the spray area.

All conductive objects in the spray area are electrically grounded and the floor of the spray area is electrically conductive and grounded.

309293K