Repair

Barrel Removal

1.Prepare the gun for service, page 41.

2.Remove the air inlet fitting (35) and take the bracket

(104)off the gun handle (17).

3.Loosen the three screws (11).

CAUTION

To avoid damaging the power supply (18), pull the gun barrel straight away from the gun handle. If nec- essary, gently move the gun barrel from side to side to free it from the gun handle.

4.Hold the gun handle (17) with one hand and pull the barrel (16) straight off the handle. See FIG. 28..

Barrel Installation

1.Be sure the gasket (10*) and grounding spring (55) are in place. Make sure the gasket air holes are aligned properly. Replace if damaged. See FIG. 29..

2.Place the barrel (16) over the power supply (18) and onto the gun handle (17).

3.Tighten the three screws (11) oppositely and evenly (about a half turn past snug).

CAUTION

Do not over-tighten the screws (11).

4.Position the bracket (104) on the gun handle (17) and secure with the air inlet fitting (35).

5.Apply dielectric grease (40) to the exposed inner tube of the fluid hose (101).

6.Check that the nut (105) is tight on the ferrule hous- ing (103).

7.Test gun resistance, page 30.

104

11

16

TI1690A

35 17

17

TI1691A

Fig. 28. Barrel Removal

*10

18

11

16

55

35

101

104

105

TI1692A

Fig. 29. Barrel Installation

46

309293K

Page 46
Image 46
Graco Inc 244582, 309293K, 244581 important safety instructions Barrel Removal, Barrel Installation