Service

Reassembly

Clean all parts thoroughly before reassembling. Check them carefully for damage or wear, replacing parts as needed. For best results replace the original parts with new parts in repair kits.

Prior to assembly, lubricate all seals and o-rings with PARKER-O-LUBE or an equivalent lubricant.

1.Connect needle (8) and stop nut (2) to yoke (1).

2.Secure yoke (1) in soft jawed vise. Lock stop nut (2) against yoke.

ti4043a

3.Insert needle (8) into packing nut (5).

4.Push three seal needles (6) in packing nut (5) using soft rod or dowel. Orient as shown below

ti4045a

5.Install o-ring (4) on groove of packing nut (5).

6.Install guide (22) on needle (8).

7.Rewind spiral o-ring backup (21) on guide (22).

8.Install two o-rings (23) on guide (22).

9.Insert cartridge assembly in gun body (17) from rear of gun.

10.Screw packing nut (5) into gun body (17).

11.Insert valve (20) through front of gun on needle (8).

ti4050a

12. Tighten nut (19) on needle (8).

ti4051a

13.Adjust screw (3) to tighten packings.

14.Install trigger (18). Align yoke (1) in gun body (17).

15.Press trigger pin (12) into gun body.

16.Secure trigger pins (12) using screws (11) and lock washers (28).

17.Install spring (13) and spring retainer (15) into gun body (17).

18.Adjust spring retainer to allow approximately 1/32 in. of free play on trigger.

19.Tighten stop nut (14).

20.Install o-ring (10) on adapter (9).

21.With trigger retracted screw adapter (9) on gun body

22.While holding adapter (9) stationary, screw collar

(16)and nozzle into adapter. Do not over tighten collar.

23.Reconnect flow gun to material supply line.

24.Turn on material supply line to gun.

25.Return flow gun to normal operating condition.

10

309739

Page 10
Image 10
Graco Inc 309739D, ti3795a, ti4057a, ti3810a, 12006, 12004X, 12005 important safety instructions Reassembly