Spray Pattern Troubleshooting

Troubleshooting

Spray Pattern Troubleshooting

NOTE: Some spray pattern problems are caused by the improper balance between air and fluid.

Problem

Cause

Solution

Fluttering or spitting spray

The fluid supply is insufficient.

Adjust the fluid regulator, or fill the

 

fluid supply.

 

 

 

 

 

 

 

 

 

 

 

 

The fluid nozzle is loose, or the fluid

Tighten or replace the fluid nozzle;

 

 

 

nozzle taper seat is damaged.

see page 30.

 

 

 

 

 

 

 

 

There is dirt between the fluid nozzle,

Clean the parts; see page 21.

 

 

 

 

 

 

 

 

 

taper seat, and gun body.

 

 

 

 

 

 

 

 

 

The coupler at the fluid inlet is loose

Tighten or repair the coupler.

 

 

 

or cracked.

 

 

 

 

 

 

Improper spray pattern

There is fluid build-up on the air cap;

Clean the air cap with a soft imple-

 

 

 

partially clogged horn holes; or full air

ment or submerge it in water and

 

 

 

pressure from the clean horn hole

wipe it clean; see page 21.

 

 

 

forces the fan pattern toward the

 

 

 

 

clogged end.

 

 

 

 

 

 

 

 

 

The electrode is bent.

Straighten the electrode.

 

 

 

 

 

 

 

 

The fluid nozzle or air cap holes are

Replace the damaged part; see page

 

 

 

damaged.

30.

 

 

 

 

 

 

 

 

There is fluid buildup on the perimeter

Remove the obstruction; never use

 

 

 

of the fluid nozzle orifice, or a partially

wire or hard instruments; see page

 

 

 

clogged fluid nozzle orifice.

21.

 

 

 

 

 

 

 

 

The electrode is bent.

Straighten the electrode wire.

 

 

 

 

 

 

 

 

The fan air pressure is too high.

Reduce the fan air pressure.

 

 

 

 

 

 

 

 

The fluid is too thin.

Reduce the fluid viscosity.

 

 

 

 

 

 

 

 

There is not enough fluid pressure.

Increase the fluid pressure.

 

 

 

 

 

 

 

 

The fan air pressure is too low.

Increase the fan air pressure.

 

 

 

 

 

 

 

 

The fluid is too thick.

Reduce the fluid viscosity.

 

 

 

 

 

 

 

 

There is too much fluid.

Reduce the fluid flow.

 

 

 

Streaks

The last coat of fluid is applied too

Apply a drier finish using multiple

 

 

 

wet.

strokes.

 

 

 

 

 

 

 

 

 

 

 

There is too much air pressure.

Decrease the air pressure.

 

 

 

 

 

 

 

 

The air pressure is insufficient.

Increase the air pressure.

 

 

 

 

 

 

 

 

The spray pattern is non-uniform.

Clean or replace the air cap; see

 

 

 

 

page 21.

 

 

 

 

 