TROUBLESHOOTING
SYMPTOM |
| POSSIBLE CAUSE | CORRECTIVE ACTION | ||
|
|
|
|
| |
Motor will not start. | 1. | Low voltage. | 1. | Check power line for proper voltage. | |
|
| 2. | Open circuit in motor, control | 2. | Inspect all lead connections on motor, switch and |
|
|
| panel or magnetic starter. |
| starter for loose or open connections. |
|
|
|
|
| |
Motor will not start; fuses | 1. | Short circuit in line cord or | 1. | Inspect cord or plug for damaged insulation and | |
or circuit breakers blow. |
| plug. |
| shorted wires. | |
|
| 2. | Short circuit in motor or loose | 2. | Inspect all connections on motor for loose or shorted |
|
|
| connections. |
| terminals or worn insulation. |
|
| 3. | Incorrect fuses or circuit break- | 3. | Install correct fuses or circuit breakers. |
|
|
| ers in power line. |
|
|
|
|
|
|
|
|
Motor overheats. |
|
|
| 1. | Reduce load on motor. |
|
| 1. | Motor overloaded. | 2. | Clean out motor to provide normal air circulation. |
|
| 2. | Air circulation through the motor |
|
|
|
|
| restricted. |
|
|
Motor stalls (resulting in |
|
| 1. | Inspect connections on motor for loose or shorted | |
blown fuses or | tripped | 1. | Short circuit in motor or loose |
| terminals or worn insulation. |
circuit). |
|
| connections. | 2 | Correct the low voltage conditions. |
|
| 2. | Low voltage. | 3. | Install correct fuses or circuit breakers. |
|
| 3. | Incorrect fuses or circuit break- |
|
|
|
|
| ers in power line. | 4. | Reduce load on motor. |
|
| 4. | Motor overloaded. |
|
|
Motor and blade | speed |
|
| 1. | Adjust spring tension to reduce feed pressure.- |
slows when operating. | 1. | Excessive feed pressure. | 2. | Replace blade. | |
|
| 2. | Blade is dull. |
|
|
|
|
|
|
|
|
G1011 7" x 12'' Bandsaw |