Grizzly G1073/G1073Z Circuit Requirements, 220V Operation 110V Operation, Extension Cords

Models: G1073/G1073Z

1 48
Download 48 pages 23.79 Kb
Page 7
Image 7

SECTION 2: CIRCUIT REQUIREMENTS

220V Operation

 

110V Operation

 

 

 

 

 

 

The Model G1073/G1073Z Bandsaw is supplied with a dual-voltage 110V/220V motor, prewired for 220V operation. Under normal use, the motor draws approximately 12 amps at 220V. We rec- ommend a 15 amp circuit breaker or slow-blow fuse for 220V. This should be satisfactory for nor- mal use, while providing enough protection against damage caused by an overloaded circuit. If frequent circuit failures occur when using the bandsaw, contact our service department or your local electrical contractor.

The Model G1073/G1073Z Bandsaw is not sup- plied with a power plug. We recommend using a NEMA-style L6-15 plug and outlet similar to the one shown in Figure 1. You may also Òhard-wireÓ the bandsaw directly to your panel, provided you place a disconnect near the machine.

Figure 1. Typical 220V 3-prong plug and outlet.

Be sure that your particular electrical config- uration complies with local and state codes. The best way to ensure compliance is to check with your local municipality or licensed electrician.

If 110 volt operation is desired, refer to the wiring diagram in the back of this manual. Under normal use, the motor draws approximately 24 amps at 110V. We recommend using a circuit breaker and wires rated for 30 amps. This should be satisfac- tory for normal use, while providing enough pro- tection against damage caused by power surges. If frequent circuit failures occur when using the bandsaw, contact our service department or your local electrical contractor.

The Model G1073/G1073Z is not supplied with a power plug. It will be necessary to supply your own standard 110V, 30 Amp grounded plug and receptacle as shown in Figure 2.

Extension Cords

We do not recommend the use of extension cords on 220V equipment. It is much better to arrange the placement of your equipment and the installed wiring to eliminate the need for exten- sion cords. Should it be necessary to use an extension, make sure the cord is rated Hard Service (Grade S) or better. Refer to the chart on page 3 to determine the minimum gauge for the extension cord. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.

G1073/G1073Z 16'' Bandsaw

-5-

Page 7
Image 7
Grizzly G1073/G1073Z instruction manual Circuit Requirements, 220V Operation 110V Operation, Extension Cords