Basic Adjustment of the Polarmount Aerial
| System 1 | 
 | 
| 14/18 V | |
| Frequency switching with | 12/0 V | 
| 0/22 kHz | |
| 
 | 
 | 
| 14/18 V, e.g., Grundig package STP 400/STP 300 A, | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 11/12 | 
 | 
 | 
 | 
 | ||||||||||
| or 0/12 V, e.g., Grundig package STP 300, | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | GHz | 
 | 
 | A | |||||||||
| or with 0/22 kHz, e.g., future Astra solution. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 
 | 
 | 
 | magnetic or  | 
 | 
 | 910. . .2050MHz | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | polarizer | 
 | 
 | |||||
| Polarization switching: | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 14/19V 0.5A | |||||||
| 
 | 
 | 
 | 
 | 
 | possible connection for second aerial | B | ||||||||||
| exclusively with  | 
 | 
 | 
 | 
 | 
 | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||||
| or magnetic polarizer. | 
 | 
 | 
 | 
 | 
 | with control according to sytem 1 or 2. | ON | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| Frequency | 
 | Polarization | 
 | LNC power | 
 | Preprogrammed | 
 | Preprogrammed | 
 | 
 | Switching | frequency | ||||
| 
 | 
 | 
 | 
 | 
 | ||||||||||||
| range | 
 | 
 | 
 | 
 | 
 | skew value | 
 | switching voltage value | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 11 GHz | 
 | V1 (vertical 1) | 
 | 14 V | 
 | approx. +30 mA | 
 | 12 V | 
 | 
 | 10 kHz | 
 | 
 | 
 | ||
| 11 GHz | 
 | H1 (horizontal 1) | 
 | 14 V | 
 | approx.  | 
 | 12 V | 
 | 
 | 10 kHz | 
 | 
 | 
 | ||
| 12 GHz | 
 | V2 | 
 | 18 V | 
 | approx. +18 mA | 
 | 10 V | 
 | 
 | 22 kHz | 
 | 
 | 
 | ||
| 12 GHZ | 
 | H2 | 
 | 18 V | 
 | approx.  | 
 | 10 V | 
 | 
 | 22 kHz | 
 | 
 | 
 | ||
| System 2 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 12/0 V | 
 | 
 | 
 | 
 | 
 | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||||
| Frequency switching with | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 0/22 kHz | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||||
| 0/12 V or | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 11/12 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||||
| 0/22 kHz | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | GHz | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | A | 
 | 
 | 
 | |||||||
| Polarization switching with | 
 | 
 | 
 | 
 | 
 | 
 | magnetic | or motor- | driven | 14/19V | 0.5A | ||||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | polarizer or 14/18 V | 
 | 
 | |||||||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 910. . .2050MHz | |||||
| 14/18 V or | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | possible connection for second aerial | B | 
 | 
 | 
 | ||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||||||||||
| 
 | 
 | 
 | 
 | 
 | with control according to sytem 1 or 2. | 
 | 
 | 
 | ON | ||||||||||||||||
| The switching frequency 0/22 kHz can | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||
| also be used for driving a coaxial relay. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| Frequency | 
 | 
 | Polarization | 
 | 
 | LNC power | 
 | Preprogrammed | 
 | 
 | Preprogrammed | 
 | 
 | Switching | frequency | ||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||||||||||||
| range | 
 | 
 | 
 | 
 | 
 | 
 | 
 | skew value | 
 | 
 | switching voltage value | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 11 GHz | 
 | 
 | V1 (vertikal 1) | 
 | 
 | 14 V | 
 | approx. +30 mA | 
 | 
 | 12 V | 
 | 
 | 10 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 11 GHz | 
 | 
 | H1 (horizontal 1) | 
 | 
 | 18 V | 
 | approx.  | 
 | 
 | 12 V | 
 | 
 | 10 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 12 GHz | 
 | 
 | V2 | 
 | 
 | 14 V | 
 | approx. +18 mA | 
 | 
 | 10 V | 
 | 
 | 22 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 12 GHZ | 
 | 
 | H2 | 
 | 
 | 18 V | 
 | approx.  | 
 | 
 | 10 V | 
 | 
 | 22 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| System 3 | 
 | 
 | 
 | 
 | 
 | 
 | magnetic or  | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | polarizer or 14/18 V | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||||||
| Frequency switching with input A/B for systems with | 
 | 
 | 
 | 
 | 
 | 
 | 11 GHz | 
 | 
 | 
 | |||||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | A | 
 | 
 | 
 | ||||||||||||||
| 2 LNC´s (A: 11 GHz, B: 12 GHz) and waveguide filter. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 910. . .2050MHz | ||||||||||||
| Polarization switching with | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 14/19V | 0.5A | ||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 12 GHz | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||
| 14/18 V or | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | B | 
 | 
 | 
 | |||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | waveguide filter | 
 | 
 | 
 | 
 | 
 | |||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ON | ||||||||||||||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| Frequency | 
 | 
 | Polarization | 
 | 
 | LNC power | 
 | Preprogrammed | 
 | 
 | Preprogrammed | 
 | 
 | Switching frequency | |||||||||||
| 
 | 
 | 
 | 
 | 
 | |||||||||||||||||||||
| range | 
 | 
 | 
 | 
 | 
 | 
 | 
 | skew value | 
 | 
 | switching voltage value | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||||
| 11 GHz | 
 | 
 | V1 (vertikal 1) | 
 | 
 | 14 V | 
 | approx. +30 mA | 
 | 
 | 12 V | 
 | 
 | 10 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 11 GHz | 
 | 
 | H1 (horizontal 1) | 
 | 
 | 18 V | 
 | approx.  | 
 | 
 | 12 V | 
 | 
 | 10 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 12 GHz | 
 | 
 | V2 | 
 | 
 | 14 V | 
 | approx. +18 mA | 
 | 
 | 10 V | 
 | 
 | 22 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
| 12 GHZ | 
 | 
 | H2 | 
 | 
 | 18 V | 
 | approx.  | 
 | 
 | 10 V | 
 | 
 | 22 kHz | 
 | 
 | 
 | 
 | 
 | 
 | |||||
It is possible to allocate the inputs A/B to sytem 1 or system 2 as desired (make the corresponding adjustments in the installation menu). For system 3, allocation of the inputs A and B is predetermined.
The LNC power 14/18 V and the switching voltage 0/22 kHz are transferred via the coaxial cable which is connected to input A or B. The 0/12 V switching voltage and the control signals for a 
13