if not eliminate water odour problems. The water supply sys- tem may require special filtration equipment from a water conditioning company to successfully eliminate all water odour problems.

Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and cal- cium ions. The use of a water softener may decrease the life of the water heater tank. The anode should be inspected periodically. If the anode is more than 50% depleted, the anode should be replaced.

VI) MAINTENANCE

Draining and Flushing

It is recommended that the tank be drained and flushed every 6 months to remove sediment which may buildup dur- ing operation. The water heater should be drained if being shut down for extended periods of time. To drain the tank, perform the following steps:

1.Turn off the gas to the water heater with the manual gas shut-off valve.

2.Close the cold water inlet valve.

3.Open a nearby hot water faucet.

4.Connect a hose to the drain valve and terminate it to an adequate drain.

Note: The drain hose should be rated for at least 94°C (200°F). If the drain hose does not have this rating, open the cold water inlet valve and nearby hot faucet until the water is no longer hot.

5.Open the water heater drain valve and allow all the water to drain from the tank. Flush the tank with water as needed to remove sediment.

6.Close the drain valve, refill the tank, and restart the heater as directed under “Operating Instructions”. If the water heater is going to be shut down for an extended period, the drain valve should be left open.

Important: Condensation may occur when refilling tank and should not be confused with a tank leak.

The installation and maintenance of the water heater must comply with all of the instructions described in sections I to IX of this manual. Water heater failure that is a result of the heating system is not covered by warranty.

The following maintenance procedures are for the Flame GuardTM safety system components and should be per- formed by a qualified service technician.

Replacement parts (see Figures 20 & 21) may be ordered through your local distributor. When ordering replacement parts, always have the following information ready:

1.Model, serial and product number.

2.Type of gas.

3.Item number.

4.Parts description.

Periodic Inspection

Periodically a visual inspection should be made of the vent- ing and air supply system, piping systems, main burner, pilot burner and flame arrester.

Check the water heater for the following:

1.Obstructions, damage or deterioration in the venting system. Make sure the ventilation and combustion air supplies are not obstructed.

2.Build-up of soot and carbon on the main burner and pilot burner. Check for a soft blue flame.

3.Leaking or damaged water and gas piping.

4.Presence of flammable or corrosive materials in the installation area.

5.Presence of combustible materials near the water heater.

6.Presence of debris on the outside of the flame arrester. See note below.

19 –

Page 19
Image 19
GSW 72090 manual VI Maintenance, Draining and Flushing, Periodic Inspection

72090 specifications

The GSW 72090 is a remarkable addition to the world of modern heating solutions, designed to provide efficient and effective space heating. It epitomizes advanced technology, reliability, and user-centric design, making it an ideal choice for homes and commercial spaces alike.

One of the main features of the GSW 72090 is its impressive heating capacity. Engineered to deliver optimal warmth, it can efficiently heat larger areas, ensuring that spaces remain comfortable even during the coldest months. The unit’s high-grade alloy construction enhances durability and helps maintain consistent performance over time.

A vital technology integrated into the GSW 72090 is its modulating control system. This system intelligently adjusts the temperature output based on the current heating demand, optimizing energy usage and contributing to lower utility bills. This efficiency not only benefits the consumer but also has a positive impact on the environment by reducing greenhouse gas emissions.

The GSW 72090 also boasts a sleek and modern aesthetic, making it an attractive addition to any space. Its design allows for easy installation and maintenance, ensuring that users can focus on comfort without worrying about the complexities of upkeep. The unit operates quietly, providing a peaceful environment without the disruptive noises often associated with traditional heating systems.

Incorporating safety features is another key characteristic of the GSW 72090. It includes overheat protection, which automatically turns the unit off if it detects excessive temperatures, ensuring a safe environment for occupants. Additionally, the product is constructed with materials that are resistant to corrosion and wear, enhancing longevity.

As an environmentally conscious option, the GSW 72090 is designed to comply with stringent energy efficiency regulations. Its performance not only meets but often exceeds the required standards, making it a smart choice for those looking to reduce their carbon footprint.

Overall, the GSW 72090 stands out due to its combination of advanced technologies, user-friendly features, aesthetic appeal, and commitment to safety and efficiency. Its multi-faceted capabilities make it a prime option for anyone seeking reliable and effective heating solutions in their home or business.