Hach 900 manual Section, Splitter Interface

Models: 900

1 52
Download 52 pages 55.68 Kb
Page 19
Image 19
Splitter Interface

Section 3

Figure 6 4–20 mA Interface and Pulse Duration Input

(+)

(-)

To Auxillary Connector

For details on programming the sampler for flow proportional operation, refer to SECTION.

Splitter Interface

This splitter interface (Cat. No. 939) can be used if access to more than one of the Auxiliary Receptacle functions is required simultaneously. Connecting the interface to the 6-pin connector on the sampler provides three additional connectors for use. Two or more interfaces may be connected in series to allow for as many connections as desired.

Figure 7 Splitter Interface

 

Page 19

8544install.fm

Auxiliary Connection

Page 19
Image 19
Hach 900 manual Section, Splitter Interface

FAQ

What is the purpose of the 420 mA Interface and Pulse Duration Input?

The 420 mA Interface and Pulse Duration Input are used for flow proportional operation. Refer to the official manual for programming details.

How can I connect multiple Auxiliary Receptacle functions simultaneously?

You can use the Cat.No.939 Splitter Interface to connect to the 6-pin connector on the sampler, providing three additional connectors for use. Multiple interfaces can be connected in series for more connections.

Where can I find more information on the Splitter Interface?