Specifications

 

Specifications are subject to change without notice.

 

 

 

Controller Dimensions

 

Height: 34 cm (13.5 in.), Width 28 cm (11 in.), Depth 20.3 cm (8 in.) without wall

 

bracket, 33 cm (13 in.) deep with wall bracket

 

 

 

 

 

Pump/Controller Housing

 

High impact injection molded ABS: submersible, watertight, dust tight, corrosion

 

and ice resistant; NEMA 4X, 6

 

 

 

 

 

Sample Pump

 

High speed peristaltic, dual roller, with 9.53 ID x 15.9 mm OD (3/8 in. x 5/8 in.)

 

medical grade silicone rubber pump tube.

 

 

 

 

 

Pump Body

 

Impact/corrosion resistant, glass reinforced Delrin

 

 

 

Vertical Lift

 

8.23 m (27 ft) maximum. Remote pump option recommended for lifts from 6.7 to

 

10.7 m (22 to 35 ft)

 

 

 

 

 

Sample Transport Velocity

 

61 mm/sec. (2 ft/sec.) minimum, at 4.6 m (15 ft) vertical lift in a 3/8 in. ID intake tube

 

 

 

Pump Flow Rate

 

60 mL/sec at 0.91 m (3 ft) vertical lift in a 3/8 in. ID intake tube

 

 

 

Sample Volume

 

Programmed in milliliters, in one mL increments from 10 to 9999 mL

 

 

 

Sample Volume Repeatability

 

From 0.3 to 6.7 m (1 to 22 ft) vertical lift +/-5 mL typical for a 100 mL sample (+/-

 

5%)

 

 

 

 

 

Sampling Modes

 

Supports 1 bottle. Composite Time, Composite Flow, and Level Actuation

 

 

 

 

 

Selectable in single increments from 1 to 9999 flow pulses (momentary contact

Interval Between Samples

 

closure 25 msec. or 5-12 V dc pulse; 4-20 mA interface optional), or 1 to 9999

 

 

minutes in one minute increments.

 

 

 

Intake Purge

 

Air purged automatically before and after each sample; duration automatically

 

compensated for varying intake line lengths.

 

 

 

 

 

Control Panel

 

18 key, 31 function membrane switch keypad with 18 character alphanumeric, liquid

 

crystal display. Self prompting/menu driven program.

 

 

 

 

 

Internal Clock

 

Indicated real time and date; 0.007% time base accuracy

 

 

 

Programmable Delay

 

Programmable sampler start time/date

 

 

 

Manual Sample

 

Initiates a sample collection independent of program process

 

 

 

 

 

Records program start time and date, stores up to 400 sample collection

Data Logging

 

times/dates, all program entries, operational status including number of minutes or

 

pulses to next sample, bottle number, number of samples collected, number

 

 

 

 

remaining, sample identification number.

 

 

 

Automatic Shutdown

 

Composite Mode: After preset number of samples have been delivered to

 

composite container, from 1 to 9999 samples, or upon full container.

 

 

 

 

 

Intake Tubing

 

6.4 mm (1/4 in.) and 9.5 mm (3/8 in.) ID vinyl to 9.5 mm (3/8 in.) ID Teflon-lined

 

polyethylene with protective outer cover

 

 

 

 

 

Intake Strainers

 

Choice of Teflon and 316 stainless construction, and all 316 stainless steel in

 

standard size and low profile for shallow depth applications

 

 

 

 

 

Power Requirements

 

12 V dc-supplied by optional ac power converter or battery. Average current draw

 

with pump running: 2.25 amps dc, without pump running: 4 mA dc

 

 

 

 

 

ac Power Backup

 

Rechargeable 6 amp-hour gel lead acid battery takes over automatically with ac

 

line power failure. Integral trickle charger maintains battery at full charge

 

 

 

 

 

Internal Battery

 

1.5 V dc lithium battery; maintains program logic and real time clock for five years.

 

 

Internal battery current draws less than 40 micro amps

Overload Protection

 

5 amp dc line fuse; ac power pack; internal 1 amp ac line fuse

 

 

 

Temperature Range

 

General use: 0° to 50° C (32° to 122° F). LCD display operated from –10° to 70° C;

 

Storage –40° to 80° C

 

 

 

 

 

 

Page 5

8544specs.fm

Specifications

Page 5
Image 5
Hach 900 manual Section, Specifications

FAQ

What are the controller dimensions?

The controller dimensions are 34 cm in height, 28 cm in width, and 20.3 cm in depth without the wall bracket, and 33 cm deep with the wall bracket.

What is the pump flow rate?

The pump flow rate is 60 mL/sec at a 3 ft vertical lift in a 3/8 in.ID intake tube.

What power requirements does the Hach 900 have?

The Hach 900 requires 12V DC power, supplied by an optional AC power converter or battery, with an average current draw of 2.25 amps DC with the pump running.