Installation
309292L 11
244919 HC Conversion Kit
Part No. 244919 Conversion Kit converts PRO Xs3
standard coating guns (Part Nos. 244400 and 244579)
to high conductivity guns (244575 and 244576). For fur-
ther instruction and parts, see manual 309453.
The kit is for use with fluids with low resistivity values.
1. Turn the ES ON/OFF valve OFF.
2. Flush and relieve the pressure.
3. Disconnect the fluid and air lines to the gun.
4. Remove the fluid tube and fittings.
5. Remove the fluid inlet bracket.
6. Install the new bracket (3) from the kit loosely. See
FIG. 3.
7. Place the spacer (5) in the barrel inlet. Apply Graco
dielectric grease (4) to the o-rings (2a, 2b) and to
both threads of the fluid fitting (2). Thread the fitting
into the barrel inlet.
8. Thread the nut (1d) onto the fitting (2). Make sure
the ferrules (1c and 1b) are on the tube (1a) and are
seated on the fitting (2) before tightening the nut
(1d).
9. Slide the tube case (1e) onto the barrel inlet, over
the o-ring (2b). The coiled tube (1a) will compress
slightly.
10. Insert the end of the coiled tube (1a) into the bracket
(3). Make sure the ferrules (1c, 1b) seat on the
bracket.
11. Secure the bracket by tightening the swivel (A).
Tighten the nut (1d). Reinstall the exhaust tube (B)
and clamp (C).
12. Reconnect the fluid and air lines to the gun.
WARN ING
Pressurized Equipment Hazard
To reduce the risk of an injury, follow the
Pressure Relief Procedure in your gun
manual before installing this kit.
FIG. 3: 244919 Conversion Kit
1a
1e
5
2a
2b
21b1c
1d
1e
1e 1e 1e
C
B
3
A
ti10674a