Repair

Electrode Replacement

1.Prepare the gun for service, page 25.

2.Remove the air cap and nozzle, page 26.

3.Unscrew the electrode (29) with the multi-tool (37). Hold the packing rod end (26h) to prevent it from turning, FIG. 12.

37

CAUTION

To avoid damaging the plastic threads, be very careful when installing the electrode.

4.Apply low-strength (purple) Loctite® or equivalent thread sealant to the electrode and packing rod threads. Install the electrode finger-tight. Do not overtighten.

5. Install the fluid nozzle and air cap, page 26.

ti1502a

6. Test gun resistance, page 18.

Fig. 12. Electrode Replacement

309292L

27

Page 27
Image 27
Haier 309292L important safety instructions Electrode Replacement