Operation

Operation

Refer to the gun operation manual (supplied) for Setup, Shutdown, and Daily Care proce- dures.

INSTRUCTIONS

Low Voltage Adjustment (Smart Guns Only)

The ES HI/LO switch enables you to switch between full voltage and a lower voltage output. The lower voltage is factory set, but can be adjusted.

1.Set the ES HI/LO switch to LO.

2.Remove the LO VOLTAGE adjustment plug (53). Set the desired voltage, using a small screwdriver to slide switches 1 and 2 ON or OFF, according to Table 3 . Also see FIG. 5.

OFF

ON

2 1

0 KV 100%

μα

53

ti1529a

Fig. 5. Low Voltage Adjustment Switches

Table 3: Low Voltage Adjustment

 

 

60 kV Guns

 

85 kV Guns

 

 

 

 

 

 

 

 

 

1

 

2

kV

1

 

2

kV

 

 

 

 

 

 

 

 

 

 

ON

 

ON

50

ON

 

ON

70

 

 

 

 

 

 

 

 

 

Factory

ON

 

OFF

40

ON

 

OFF

60

 

 

 

 

 

 

 

 

OFF

 

ON

35

OFF

 

ON

50

Setting

 

 

 

 

 

 

 

 

 

 

 

OFF

 

OFF

30

OFF

 

OFF

40

 

 

 

 

 

 

 

 

 

309292L

15

Page 15
Image 15
Haier 309292L important safety instructions Operation, Low Voltage Adjustment Smart Guns Only, KV Guns