Connect the Air Line
WARNING
Electric Shock Hazard
To reduce the risk of electric shock or other serious injury, the air supply hose must be electrically connected to a true earth ground. Use only Graco Grounded Air
Supply Hose.
1.Connect the Graco Grounded Air Supply Hose (R) between the air supply line and the gun's air inlet
(V). The gun air inlet fitting has a
2.Install an air line filter/water separator (O) on the gun air line to ensure a dry, clean air supply to the gun. Dirt and moisture can ruin the appearance of your finished workpiece and can cause the gun to malfunction.
3.Install a
Installation
4.Install a
WARNING
Pressurized Equipment Hazard
The
5.Install an air shutoff valve ( P) on each gun air sup- ply line to shut off air to the gun(s).
Connect the Exhaust Tube
Press the exhaust tube (38) onto the barbed adapter on the bottom of the gun handle. Secure the tube with the clamp (39).
309292L | 9 |