Installation procedure
Install indoor unit
<The wiring method of the connection of the unit>
Connect the unit
Remove the electric box cover (1), draw the wire in the rubber lining, use wire clamp A to clamp it together with other wires, and connect the wire of the relative polarity to the inner power terminal block.
After proper connection, press the wire clamp A tight.
Bind the seal cushion on the wire. (it must be bound tight to avoid
After proper connection, reinstall the electric box cover (1).
Power terminal block
Power terminal block Wire clamp A
Grounding wire end
Rubber lining
Electric box cover (1)
This part must be sealed to prevent water from entering
Rubber lining Instruction: Use seal cushion to bind tight not leaving any gap
| Seal cushion (little size) bind the wire |
(inside) | (outside) |
Attached with seal cushion | Wiring on site |