When Troubles Occur

When Troubles Occur

Before contacting the commissioned repair center for after-sales service, please check your air conditioner according to the following items.

Symptom

 

Cause

Solution

The unit does not

 

The fuse is blown out or the breaker

Change the fuse or close the

operate.

 

is open.

breaker.

Once the unit operates, it

The air inlet or air outlet of indoor

Remove the obstacles.

stops immediately.

 

or outdoor unit is blocked.

 

A b n o r m a l

o f

The air inlet or air outlet of indoor

Remove the obstacles.

or outdoor unit is blocked.

C O O L I N G

o r

Improper set temperature

Referring to page 8

HEATING.

 

 

 

 

The fan speed is set too low

Referring to page 8

 

 

 

 

Incorrect swing direction

Referring to page 9

 

 

The doors or windows are open

Close them

*COOLING*

Direct sunshine

Hang the curtain or blinds before

windows

*COOLING*

 

Too much people in room

 

*COOLING*

Too many heat sources in room

 

Trouble display

 

 

 

Phenomenon of outdoor unit trouble

The flashing time of indicator light on

outdoor control panel

 

The trouble of outdoor ambient temperature sensor

1 (A, B systems indicate together)

The trouble of outdoor coil temperature sensor

2 (A and B system indicate individually)

The trouble of outdoor discharging air temperature

3 (A and B system indicate individually)

sensor

 

The outdoor discharging air temperature is too high

4 (A and B system indicate individually)

Over electric current protection

5 (A and B system indicate individually)

CT wire breaks

6 (A and B system indicate individually)

Detection of abnormal phase sequence

7 (A and B system indicate together)

The communication trouble between indoor and

8 (A and B system indicate individually)

outdoor unit

 

The protection of too high (too low) pressure

9 (A and B system indicate individually)

Phenomenon of indoor unit trouble

Trouble indication on remote control

type indoor unit

 

The trouble of indoor ambient temperature sensor

The compressor indicator light flashes 1 time

in 0.2S/time frequency

 

The trouble of indoor coil temperature sensor

The compressor indicator light flashes 2 time

in 0.2S/time frequency

 

The trouble of outdoor ambient temperature sensor

The compressor indicator light flashes 3 time

in 0.2S/time frequency

 

The trouble of outdoor coil temperature sensor

The compressor indicator light flashes 4 time

in 0.2S/time frequency

 

The trouble of electric current overload

The compressor indicator light flashes 5 time

in 0.2S/time frequency

 

Over voltage protection

The compressor indicator light flashes 6 time

in 0.2S/time frequency

 

Excessive and lack voltage protection

The compressor indicator light flashes 7 time

in 0.2S/time frequency

 

The communication trouble between panel and indoor

The compressor indicator light flashes 8 time

panel

in 0.2S/time frequency

The communication trouble between indoor panel and

The compressor indicator light flashes 9 time

outdoor panel

in 0.2S/time frequency

The trouble of water pump

The compressor indicator light flashes 10 time

in 0.2S/time frequency

 

20

Page 22
Image 22
Haier AB422BCBAA manual When Troubles Occur, Trouble display, Symptom, Cause, Solution, Phenomenon of outdoor unit trouble