Tripp Lite APS 612 owner manual Switches, Indicator Lights & Other Features continued

Models: APS 612

1 28
Download 28 pages 18.45 Kb
Page 10
Image 10
Switches, Indicator Lights & Other Features continued

Switches, Indicator Lights & Other Features continued

Other Features

7.DC Power Terminals: These terminals should be wired to your battery terminals. See “Battery Connection”, p. 7 for instructions.

8.AC Input Line Cord: NEMA 5-15P fixed: This cord should be plugged into a 120V, 60 Hz, dedicated 15 Amp AC utility outlet. DO NOT plug the cord into the APS’s AC receptacles.

9.AC Receptacles: NEMA 5-15R: These receptacles allow you to connect equipment that would normally be plugged into a utility outlet.

10.Resettable Circuit Breakers: These circuit breakers protect your APS against damage due to input or output overload.The Input (Charge) Breaker helps protect the charge input only. The Output (Load) Breaker helps prevent output overload. If a circuit breaker trips, wait 1 minute to allow components to cool before resetting it. If the Output Breaker trips, remove overload by plugging in equipment with a lower total wattage draw before resetting.

11.Remote Module Connector: The front panel has an RJ45 receptacle for use with the optional remote module.See the installation instructions packed with the remote module.

12.Mounting Flanges: Use mounting flanges (located on the front of unit) and mounting slots (located on the bottom rear of the unit) to permanently mount your APS. Mount to a sturdy, horizontal surface using user-supplied screws.

10

Page 10
Image 10
Tripp Lite APS 612 owner manual Switches, Indicator Lights & Other Features continued