Troubleshooting

Failure code(from receive board)

Failure code(from wired Failure code(from

Trouble shooting

Possible reasons

 

 

controller)

panel controller)

 

 

Flash times of

Flash times of

 

 

Timing LED(or

Running LED(or

 

 

 

 

indoor PCB LED4)

indoor PCB LED3)

 

 

 

 

 

 

 

 

 

 

0

1

01

E1

Temperature sensor Ta faulty

Sensor disconected,or broken,or

 

 

 

 

 

at wrong position,or short circuit

 

 

 

 

 

 

0

2

02

E2

Temperature sensor Te faulty

Sensor disconected,or broken,or

 

 

 

 

 

at wrong position,or short circuit

 

 

 

 

 

 

0

4

04

F8

EEPROM WRONG

Faulty indoor unit PCB

 

 

 

 

 

 

0

7

07

E9

Abnormal communication

Wrong connection,or the wires be

 

 

 

 

between indoor and outdoor

disconected,or wrong address

 

 

 

 

units

setting of indoor unit,or faulty

 

 

 

 

 

power supply or faulty PCB

 

 

 

 

 

 

0

8

NO EEROR

E8

Abnormal communication

Abnormal communication between

 

 

CODE DISPLAY

 

between indoor wired controller

indoor wired controller and indoor

 

 

 

 

and indoor unit PCB

unit PCB

 

 

 

 

 

 

0

12

0C

E0

Drainage system abnormal

Pump motor disconnected,or at

 

 

 

 

 

wrong position,or the float switch

 

 

 

 

 

broken down,or the float switch

 

 

 

 

 

disconected,or at wrong position.

 

 

 

 

 

 

0

13

OD

EF

Zero cross sigal wrong

Zero cross sigal detected wrong

 

 

 

 

 

 

0

16

10

F3

Indoor mode abnormal

Different from outdoor unit mode

 

 

 

 

 

 

2

1

15

/

Outdoor unit abnormal

 

 

 

 

 

 

 

2

2

16

/

Outdoor unit abnormal

 

 

 

 

 

 

 

2

4

18

/

Outdoor unit abnormal

 

 

 

 

 

 

 

2

5

19

/

Outdoor unit abnormal

 

 

 

 

 

 

 

2

7

1B

/

Outdoor unit abnormal

 

 

 

 

 

 

 

2

8

1C

/

Outdoor unit abnormal

 

 

 

 

 

 

 

2

9

1D

/

Outdoor unit abnormal

 

 

 

 

 

 

 

3

0

1E

/

Outdoor unit abnormal

 

 

 

 

 

 

 

3

1

1F

/

Outdoor unit abnormal

 

 

 

 

 

 

 

3

2

20

/

Outdoor unit abnormal

 

 

 

 

 

 

 

3

3

21

/

Outdoor unit abnormal

 

 

 

 

 

 

 

3

5

23

/

Outdoor unit abnormal

Refer to the outdoor unit trouble

 

 

 

 

 

3

6

24

/

Outdoor unit abnormal

shooting

 

 

 

 

 

list

3

7

25

/

Outdoor unit abnormal

 

 

 

 

 

 

 

3

8

26

/

Outdoor unit abnormal

 

 

 

 

 

 

 

3

9

27

/

Outdoor unit abnormal

 

 

 

 

 

 

 

4

3

2B

/

Outdoor unit abnormal

 

 

 

 

 

 

 

4

4

2C

/

Outdoor unit abnormal

 

 

 

 

 

 

 

4

7

2F

/

Outdoor unit abnormal

 

 

 

 

 

 

 

4

8

30

/

Outdoor unit abnormal

 

 

 

 

 

 

 

4

9

31

/

Outdoor unit abnormal

 

 

 

 

 

 

 

5

8

3A

/

Outdoor unit abnormal

 

 

 

 

 

 

 

5

9

3B

/

Outdoor unit abnormal

 

 

 

 

 

 

 

6

3

3F

/

Outdoor unit abnormal

 

 

 

 

 

 

 

6

4

40

/

Outdoor unit abnormal

 

1. For the indoor failure,only running LED ON remote receiver will indicate.

2. For the outdoor failure,timer LED and running LED will indicate.timer LED of remote receiver stands for ten's place,and running LED stands for one's place.timer LED will flash firstly,2 seconds later,running LED will flash too. Afer that,4 seconds later,they will flash in turns again.Flash times equals to the failure code of outdoor plus.

20.For example,failure code of outdoor is 2,the indoor unit should display 22.As a result,timer LED flashes twice firstly,then running LED flashes twice. 3.To get much more details of outdoor unit failure,Please refer to the the outdoor unit trouble shooting list.

15

Page 17
Image 17
Haier AC36ES1ERA, AC48FS1ERA, AC60FS1ERA, AC28ES1ERA operation manual Eeprom Wrong