Haier AD422BMBAA Sleep operation, Operation instruction, Use of SLEEP function, Operation modes

Models: AD422BMBAA

1 31
Download 31 pages 31.72 Kb
Page 12
Image 12
Sleep operation

Operation instruction

Sleep operation

Before going to bed, you can press the SLEEP button, the air conditioner will operate in comfort sleep mode to make you have a sound sleep.

Before using this function, you should calibrate the clock first, otherwise, the SLEEP function will be out of order.

Use of SLEEP function

After turning on the unit, setting the working mode, then press SLEEP button to make the air conditioner have the previous Sleep time (powered on for the first time or after performing Sleep is 1h). The Sleep symbol will appear. Press time */* button, you can choose between 1~8h. Each press, it may increase/decrease 1h and will display in the humidity area with ìxhî, and display ìTimer Offî in Timer Off area and the time to turn off; press Sleep button again to cancel Sleep function. The Sleep symbol disappears.

Operation modes

1.In COOLING, DEHUMIDIFYING operation

1 hour later in SLEEP operation, the temperature will increase 1* from the set temperature, another 1 hour later increase another 1*, then the unit will operate continuous for 6 hours, then it turns off automatically. The temperature is higher than set temperature to prevent you from getting a cold.

2.In HEATING operation

1 hour later in SLEEP operation, the temperature will decrease 2* from the set temperature, another 1 hour later increase another 2*, then the unit will operate continuous at this temperature for 3 hours, then it increases 1*, after operating at this temperature for another 3 hours, the unit will turn off automatically. The temperature is lower than set temperature to prevent you from feeling uncomfortable during sleep.

SLEEP operation starts

SLEEP operation stops

 

about 6 hours

1 hour

increase 1*

1 hour

increase 1*

 

Set temperature

turn off

in COOLING* DEHUMIDIFYING operation

Set temperature

turn off

1 hour

decrease 2*

 

 

1 hour

 

 

decrease 2*

 

 

about 3 hours

 

3 hours

increase 1*

SLEEP operation starts SLEEP operation stops in HEATING operation

MODE FAN SWING

TEMP

CLOCK SET

SET

TIMER

SLEEP

FILTER RESET RESET

ON/OFF

Note:

•After setting Sleep function, it is not permitted to adjust clock.

•The Sleep time is less than 8h, after reaching the set time, the unit will automatically stop. •Set Sleep function after setting ìTimer Offî function, the air conditioner will perform

Sleep function.

•After setting Sleep function, the Timer function cannot be set.

•Set Sleep function after setting ìTimer Onî function, the Sleep function can only be set in the set time of Timer On.