Haier AD422BMBAA manual When Troubles Occur, After taking the following measure

Models: AD422BMBAA

1 31
Download 31 pages 31.72 Kb
Page 18
Image 18
After taking the following measure,

When Troubles Occur

When the following phenomena appear, please contact the commissioned repair center. Manual background Warning

Manual background If finding any abnormal phenomena (such as adust smell), cut off power first, then ask the after-sales service workers for help.

Manual background If still using the air conditioner in this condition, the air conditioner may be damaged and causes electric shock or fire accident.

Symptom

After taking the following measure,

then contact the commissioned repair

 

 

center

The safety equipment, such as fuse, bre-

Cut off power.

aker and creepage breaker, has been open

 

circuit for many times; or the operation

 

switch cannot work normally.

 

 

Cut off power and inform the comm-

The air conditioner leaks water.

issioned repair center.

Trouble code display

Phenomenon of

The flashing time of indicator light Indoor control

outdoor unit trouble

on outdoor control panel

panel indication

The trouble of outdoor ambient

1 (A, B systems indicate together)

E3

temperature sensor

The trouble of outdoor coil

2 (A and B system indicate individually)

E4

temperature sensor

The trouble of outdoor discharging

3 (A and B system indicate individually)

E4

air temperature sensor

 

 

The outdoor discharging air

4 (A and B system indicate individually)

E4

temperature is too high

 

 

Over electric current protection

5 (A and B system indicate individually)

E5

CT wire breaks

6 (A and B system indicate individually)

E5

The communication trouble

8 (A and B system indicate individually)

E8

between indoor and outdoor unit

 

 

Pressure protection

9 (A and B system indicate individually)

E6

Phenomenon of indoor

Trouble indication on remote

Trouble code on wire

unit trouble

control type indoor unit

control type indoor unit

The trouble of indoor ambient

The compressor indicator light flashes 1

E1

temperature sensor

time in 0.2S/time frequency

 

The trouble of indoor coil

The compressor indicator light flashes 2

E2

temperature sensor

time in 0.2S/time frequency

 

The trouble of outdoor ambient

The compressor indicator light flashes 3

E3

temperature sensor

time in 0.2S/time frequency

 

The trouble of outdoor coil

The compressor indicator light flashes 4

E4

temperature sensor

time in 0.2S/time frequency

 

The trouble of electric current

The compressor indicator light flashes 5

E5

overload

time in 0.2S/time frequency

 

The trouble of

The compressor indicator light flashes 6

E6

overloadPressure protection

time in 0.2S/time frequency

 

 

The compressor indicator light flashes 7

E7

 

time in 0.2S/time frequency

 

 

The communication trouble

The compressor indicator light flashes 8

E8

between panel and indoor panel

time in 0.2S/time frequency

 

The communication trouble betw- The compressor indicator light flashes 9

E9

een indoor panel and outdoor panel

time in 0.2S/time frequency

 

The trouble of water pump

The compressor indicator light flashes 10

E0

time in 0.2S/time frequency

 

 

16

Page 18