Haier AD422BMBAA manual Installation procedure, Install indoor unit, Choose installation place

Models: AD422BMBAA

1 31
Download 31 pages 31.72 Kb
Page 21
Image 21
Installation procedure

Installation procedure

Install indoor unit

1.Before installation [Before finishing installation, do not throw the attached parts installation needs]

Install indoor unit Confirm the way to move the unit to the installation place.

2.Choose installation place Before moving the unit to the installation place, do not remove their packages. When have to remove the package, use a soft material or protection board with rope to lift the unit assembly to avoid unit damage or bumping a scrape.

2.Choose installation place

(1)The chosen installation place should meet the following requirements and get the userís consent.

Place ensures ideal airflow distribution. The passage of airflow has no obstacles.

The condensate water can be drained smoothly. Place can stand the weight of indoor unit. Place ensures enough space for maintenance.

The pipe length between indoor and outdoor unit is in the permitted limit (referring to outdoor unit installation part).

The indoor unit, outdoor unit, electric wire and connection wire is at least

1m away from television and radio. This is to avoid the image disturbance and noise caused by the above-mentioned home appliance. (Even if 1m away, if the electromagnetic wave is too strong, it can also cause noise.)

(2)The height of ceiling

The indoor unit can install on the ceiling, which height is no more than 2.7m. (3)Install and use the hoisting screw. Check if the installation place can bear the

weight of unit assembly. If not certain, strengthen it before install the unit.

600

100 1720

620

Ceiling opening

Obstacle

Space installation needed (unit: mm)

19

Page 21
Image 21
Haier AD422BMBAA Installation procedure, Install indoor unit, Choose installation place, Space installation needed unit mm