ELECTRIC Dryer (HDE5000AW and HDE5300AW)

4-Wire Cord Connections (US Models Only)

1.Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner.

2.Install a UL approved strain relief into the power cord entry hole of the mounting bracket . Finger tighten the nut only at this time.

3.Remove the green neutral ground wire from the green ground screw located above the terminal block.

Typical Conductor

 

 

 

 

 

Receptacle

 

Black 240V

 

 

 

 

 

 

 

 

White Neutral

 

 

 

 

 

Typical 4

 

 

 

Red 240V

 

 

 

 

 

 

 

 

Conductor Cord

 

Green Ground

16

Page 17