NOTE: The electrical supply for the dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70.

If the electrical supply available in the intended dryer location does not meet the above requirements, contact a licensed electrician.

A dryer operating on a 208 volt power supply will have longer drying times than if it were operating on a 240 volt power supply.

The dryer is not equipped with a power cord. A kit that meets local electrical codes must be purchased separately. The dryer can be Þtted with a 3 or

4-wire NEMA 14-30 or 10-30 type SRDT or ST (as required) power cord rated at 120/240 volt AC minimum, 30 amp, with 3 open-end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers.

A UL listed strain relief must be attached to the dryer to hold the power cord.

Do not use an aluminum wire receptacle with copper-wired power cord and plug (or vice versa). The proper wiring and receptacle is a copper-wired power cord with a copper-wired receptacle.

The electrical outlet should be located so that the power cord is accessible when the dryer is in the installed position.

ELECTRIC DRYER (CANADA ONLY)

WARNING

The dryer must be plugged into a properly grounded 4e, single phase, 120/240 volt, 60Hz, ACy electrical outlet connected to an individual 30cuit, fused with a 30y fuse or

circuit breaker. Do not operate a washer and dryer on the same circuit.

WARNING

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape route for the electrical current.

NOTE: The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the CSA C22.1 Canadian Electrical Code Part 1.

If the electrical supply available in the intended dryer location does not meet the above requirements, contact a licensed electrician.

Do not use an aluminum wire receptacle with copper-wired power cord and plug (or vice versa). The proper wiring and receptacle is a copper-wired power cord with a copper-wired receptacle.

The electrical outlet should be located so that the power cord is accessible when the dryer is in the installed position.