EXHAUST HOOD
•Use an approved exhaust hood with a
•Louvered or box hood styles are recommended. Angled hood styles are acceptable, but should be used only for short run installations. See the “Recommended Maximum Exhaust Length” chart for more information.
•To avoid restricting air ßow, maintain a minimum of 12” (30.5 cm) clearance between the vent hood and the ground or any other obstruction.
MOBILE HOME - ADDITIONAL REQUIREMENTS
•The installation must conform to current Manufactured Home Construction and Safety Standard, Title 24
•Special provisions must be made for outside makeup air. The opening should be at least twice as large as the dryer exhaust outlet.
•If the dryer is exhausted through the ßoor and into an enclosed area beneath the mobile home, the exhaust system must terminate outside the enclosure with the termination securely fastened to the mobile home structure.
GAS DRYER ONLY (MOBILE HOME ONLY)
•The dryer must be fastened to the ßoor using a mobile home installation kit. Follow the instructions supplied with the kit.
13