Replacing the Interface Cable
The standard interface cable is attached to the scanner with an
••Order replacement cables from Hand Held Products or from an authorized distributor.
••When ordering a replacement cable, specify the cable part number of the original interface cable.
To Replace the Interface Cable:
1.Turn the power to the host system OFF.
2.Disconnect the scanner’s cable from the terminal or computer.
3.Locate the small hole on the side of the scanner’s handle (IT3800), or on the underside of the connector pod (IT3900). This is the cable release.
4.Straighten one end of a paper clip.
5.Insert the end of the paper clip into the small hole and press in. This depresses the retention tab, releasing the connector. Pull the connector out while maintaining pressure on the paper clip, then remove the paper clip.
6.Replace with the new cable.
Insert the connector into the opening and press firmly. The connector is keyed to go in only one way, and will click into place.
Troubleshooting
Cable
Release
The scanner automatically performs
Is the power on? Is the red illumination beam on?
If the red illumination beam isn’t illuminated, check that:
1. The cable is connected properly.
14 - 2 | IT3800/3900 User’s Guide |