Cover (43). Position the Nozzle Gasket (41) against the Pipe Adapter (40). Position the proper Nozzle against the Nozzle Gasket. Then screw the Nozzle Cover back onto the Pipe Adapter to secure the Nozzle Gasket and Nozzle in place. (See Figure H.)
SANDBLASTING GUN
FIGURE H
NOZZLE
(42, 42A)
NOZZLE COVER
(43)
NOZZLE GASKET | PIPE ADAPTER |
(41) | (40) |
To Operate The Pressure Blasting System:
1.If possible, place the workpiece inside a sandblast cabinet. Otherwise, isolate the workpiece to make sure no damage can occur to nearby walls, tools, personal property, etc.
2.Turn the Media Metering Valve (18) and Air Input Valve (14) to the “OFF” position.
(See Figure G.)
3.Connect the air compressor’s hose to the previously installed Quick Connector. Then turn on the air compressor, and set its regulator between 65 to 125 PSI.
Do not exceed 125 PSI. (See Figure F.)
4.Pull up and hold the
5.Turn the Media Metering Valve (18) and Air Input Valve (14) to the “ON” position. At this point, the Tank Assembly (3) will begin to pressurize. (See Figure G.)
6.Once the Tank Assembly (3) is fully pressurized, release the
7.Grip the Sandblasting Gun firmly with both hands.
SKU 93889 For technical questions, please call | PAGE 11 |