![CLEANING THE GLASS](/images/new-backgrounds/55589/5558925x1.webp)
13
confirm that there is no blockage and that the system is in good repair. Directions for conducting a flue spillage test may be found on page 6. The vent manufacturer's instructions may provide specific suggestions or details on vent inspection. Any sections that are taken apart for the inspection must be reassembled and sealed as required.
CLEANING THE GLASS
The glass may be cleaned with ordinary house- hold glass cleaner and a soft cloth or paper towel.
WARNING: Never clean the glass when it is hot. Do not use abrasive cleaners on the glass.
CLEANING THE LOG SET AND FIREBOX
During the annual inspection and maintenance
CAUTION: If the door is opened or re- moved for servicing, it must be replaced and securely closed before operating the appli- ance. The glass must be securely fixed in the door when operating the appliance.
appointment, the service person should clean dust, lint, and any light accumulation from the logs and the firebox area. An
1.Remove the side trim panels according to the directions on page 12.
2.Remove the glass door according to the direc- tions on page 12.
3.Remove, clean, and
CONVECTION BLOWER SERVICE ACCESS
The blower is located behind a panel that can be accessed by first removing the fuel module. See page 15 for instructions. Remove the two fasteners securing the panel and pull the panel forward. The blower will come out with the panel. Disconnect the blower electrical connector to completely remove the blower from the unit.