Appendix A: Fuel Conversion
CONVERTING THE CLARITY FIREPLACE INSERT FROM ONE GAS TO ANOTHER IN THE FIELD
NOTE: THE CONVERSION SHALL BE CAR- RIED OUT IN ACCORDANCE WITH THE RE- QUIREMENTS OF THE PROVINCIAL OR LO- CAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH REQUIRE- MENTS OF THE CURRENT EDITION OF THE NATIONAL FUEL GAS CODE, ANSI Z223.1 or the
6.Install the replacement module,
After completing the fuel conversion, an installer fuel
to the stove.
CONVERSION KIT COMPONENTS
•Burner system module
•Conversion label
NATURAL
PROPANE
The Clarity Fireplace Insert is designed to burn either natural gas or propane, but requires a dedi- cated burner system module for either fuel. Conver- sion to the alternate fuel is a simple matter of replac- ing one burner system module with another. A label on the burner system module will specify for which fuel it is intended.
To accomplish the conversion procedure, follow these steps.
1.Remove the trim panels and the glass door ac- cording to the directions on page 12.
2.Disconnect the electrical connections and the gas line fitting from the module.
3.Remove the cross log, the front logs, and the two ember strips following the directions on page 7.
4.Pull the module out an inch or so so that there is enough room to remove the rear log.
5.Remove the Burner System Module
The module can be removed as an integrated unit by simply pulling the module forward.
HARMAN CLARITY GAS
FIREPLACE INSERT
44
The above label on the Clarity's burnersystem module indicates that the unit is equipped to burn natural gas. A similar label is used for Propane.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ER- RORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
SEE WIRING DIAGRAM ON PAGE 18