Log Positions When Assembled
Install the center log so that it goes all the way to the back and is centered. When properly posi- tioned, there should be an even gap along the front of the center burner in the cavity in the log. A small portion of the log support frame will be revealed. The center log has a round viewing port in the left end through which the pilot can be observed.
Install the cross log, making sure that it is ori- ented with the forked end toward the left rear of the stove, and slip it over the front locator pin and position as shown below.
Re-install and Secure the Glass door
NOTE: The glass door is heavy. Lift it carefully to prevent damage. Center the glass on the opening and suspend it in place by placing the tab hooks over the top edge of the opening. Press the glass slightly against the stove to confirm that it seats properly, then press it firmly against the front while pushing the levers to the rear to engage them.
8
INSERT TO A GAS SUPPLY
Burn Only the Fuel for Which the Heater is Equipped The Clarity Fireplace Insert will burn either natural gas or propane, but requires a dedicated burner system module for either fuel. The label on
the burner system module indicates the fuel for which it is equipped.
Making The Connection
NATURAL
PROPANE
The gas inlet is located at the bottom right rear of | |
the Insert. The inlet fitting |
|
is a 1/4" male pipe |
|
thread. |
|
A separate gas |
|
valve and a 1/8" N.P.T. |
|
plugged tapping should |
|
be installed immediately |
|
upstream of the connec- | Inlet |
tion to the appliance. |
|
The ClarityFireplace |
|
Insert must be discon- |
|
nected from the gas supply piping during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 kPa).
The Clarity gas control valve must be in the OFF position during any pressure testing of the gas supply system at pressures equal to or less than 1/2 psig (3.5 kPa).
WARNING: To avoid pipe compounds from entering into the gas train, apply compounds only to the male pipe threads and only to the first two threads.
CAUTION: TEST ALL JOINTS FOR LEAKS