Harman Stove Company 828i manual Gas Pressure Requirements, Natural Gas, LPG Gas, Maximum

Models: 828i

1 23
Download 23 pages 34.4 Kb
Page 9
Image 9
Gas Pressure Requirements

BEFORE OPERATING

Gas Pressure Requirements

Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient performance of this appliance. Make sure that the plumber or gas supplier checks the gas sup- ply line and gas pressure at installation.

NOTE: Improper gas pressure can affect heater performance, flame color, or cause pilot outage.

Natural Gas:

Maximum inlet pressure 7.0" w.c. (1.74 kPa) Minimum inlet pressure 5.0" w.c. (1.25 kPa) Gas manifold pressure 3.5" w.c. (0.87 kPa)

LPG Gas:

Maximum inlet pressure 13" w.c. (3.24 kPa) Minimum inlet pressure 11" w.c. (2.74 kPa) Gas manifold pressure 10" w.c. (2.49 kPa)

DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER OR EXPOSED TO MOIS- TURE CORROSION. IMMEDIATELY CALL A QUALlFlED SERVICE TECHNICIAN TO INSPECT THE HEATER AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

NE PAS SESERVIRDE CET APPAREIL S'IL A ÉTRE PLONGÉ DANS L'EAU, COMPLÉTEMENT OU EN PARTIE. APPELER UN TECHNICIEN QUALIFIÉ POUR INSPECTER L'APPAREIL ET REMPLACER TOUTEPARTIE DU SYSTÈME DE CONTRÔLE ET TOUTECOMMANDEQUIONT ÉTÉPLONGÉSDANS L'LAU.

CONNECTING THE CORDSET

RECOMMENDED GAS PIPE DIAMETER

 

Pipe Length

Schedule 40 Pipe

Tubing, Type L

(Feet)

Inside Diameter

Outside Diameter

 

N.G.

L.P.

N.G.

L.P.

0-10

1/2"

3/8"

1/2"

3/8"

 

1.3

cm

1.0

cm

1.3

cm

1.0

cm

10-40

1/2"

1/2"

5/8"

1/2"

 

1.3

cm

1.3

cm

1.6

cm

1.3

cm

40-100

1/2"

1/2"

3/4"

1/2"

 

1.3

cm

1.3

cm

1.6

cm

1.3

cm

100-150

3/4"

1/2"

7/8"

3/4"

 

2.0

cm

1.3

cm

2.3

cm

2.0

cm

NOTE: NEVER USE PLASTIC PIPE. CHECK TO CONFIRM WHETHER YOUR LOCAL CODES ALLOW

COPPER TUBING OR GALVANIZED PIPE.

9

The Clarity Fireplace Insert, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the the current edition of the National Electrical Code, ANSI/NFPA 70 in the United States or the current Canadian Electrical Code CSA 22.1 in Canada.

This appliance is equipped with a three-prong (grounding) plug for protection against shock haz- ard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or re- move the grounding prong from the plug.

NOTE: The convection fan requires a 120 VAC supply for operation, but the heater can be operated without the fan as in the case of a power outage.

Plug the 3-prong grounded electrical cord plug into the wall outlet.

CONNECTING THE

OPTIONAL THERMOSTAT

If the optional thermostat is used, it must be plugged into the terminal strip located behind the right side air inlet grill. It can be accessed by first opening the control access door and then pulling up and forward on the air grill. The terminal block will then be visible.

When installing a millivolt control system, use only a special low resistance thermostat. Do not use a regular heating thermostat.

Be sure that all electrical connections are clean, free from corrosion, and tight. Inspect connections periodically to confirm that no corrosion has built up over time.

When properly installed and maintained, a mil- livolt control system should give many years of trouble-free service.

It is important to use wire of a gauge proper for the length of the wire:

RECOMMENDED WIRE GAUGES

Maximum

Wire

Length

Gauge

100'

14

60'

16

40'

18

25'

20

15'

22

INSTALLING THE INSERT

Page 9
Image 9
Harman Stove Company 828i manual Gas Pressure Requirements, Natural Gas, LPG Gas, Recommended Wire Gauges, Maximum