Addendum
Minimizing Smoke during loss of Power using battery
harmanTM strongly recommends installing battery
Your pellet/biomass burning appliance relies on a combustion blower to remove exhaust. A power failure will cause the combustion blower to stop. This may lead to exhaust seeping into the room. Vertical rise in the venting may provide natural draft. It is, however, no guarantee against leakage.
there are two harmanTM approved battery
uninterruptible Power Supply (uPS) UPS battery
•The APC (American Power Conversion) model #BE750G and the TrippLite model INTERNET750U are tested and approved. Other brands or models may not be compatible.
When power is lost, a fully charged UPS will power a safe, combustion blower only
provides safe
Your appliance will recognize when power is restored. What happens depends on ESP temperature and whether it is equipped with automatic ignition:
•in “Automatic” setting, units equipped with automatic ignition will respond to the set point and ESP temperature and resume normal operation.
•in “Manual” setting or for units without automatic ignition:
•If the ESP is cool, the appliance will remain shut down.
•If the fire is out and the ESP is still warm, the feeder may restart. Since the fire is out, the ESP temperature will not rise. The unit will then
•If the fire is still burning, it will resume normal operation.
Contact your dealer if you have questions about UPS compatibility with your appliance.
harman Surefire 512h battery
leakage may still occur unless your stove has been safely shut down.
cAutiOn! Always keep appliance doors and hopper lid closed and latched during operation and during power failures to minimize risk of smoke or
cAutiOn! use only harmantM approved battery