Harman Stove Company P61A manual Manual IGNITION/Operation

Models: P61A

1 44
Download 44 pages 35.62 Kb
Page 19
Image 19
P61A Pellet Stove
Igniter Switch to "MANUAL"
Room Temperature Mode
The fire will have to be lit with starting gel and a match, or started automatically, see "Automatic Opera- tion" on Page 16. Turn to "Manual" position when the ignition cycle has started.
The difference between "AUTO" Room Temperature Mode and "Manual" Room Temperature Mode is that the fire will not go out as the room temperature goes above the control board setting. The unit can only go to low burn and will remain there until it runs out of fuel or until more heat is needed and the feed rate increases. Feed rate adjustments and dial settings are the same as "AUTO" settings. The blower will shut off com- pletely if the temperature on the ESP is too low.
Igniter Switch to "MANUAL"
Stove Temperature Mode
The advantage of this mode is to allow the operator to have a large viewing fire without blowing extra heat into the room.
During operation, with the temperature dial set at #5 or less, the distribution fan will not operate. A #5 on the temperature dial and a #5 on the feed adjuster is approximately 80% output. It is not necessary to oper- ate the distribution blower below this point. This control setting allows a higher burn rate (a larger viewing fire) without an excess of hot air blowing into the room.
An example of when to use the Manual Stove Tem- perature Mode is if you want to watch a large fire and the room is already up to temperature. The Stove Temperature Mode allows you to have a larger fire and a lower sound level, without the distribution blower.
NOTE: During the use of this mode, if you keep increasing the temperature dial setting to increase the fire size, the distribution blower will automati- cally come on when the ESP Temperature reaches 350o F, or 81% output.
NOTE: When starting the unit in the "AUTO" mode and switching to "MANUAL", the ignition cycle must be allowed to begin prior to making the switch.

Manual IGNITION/Operation

The P61A Pellet Stove is capable of manual operation. This also allows the operator to manually control operation during an emergency (i.e. igniter failure, when using a 502H battery backup, as opposed to the 512H, or when using certain generators.)

The unit can be switched between "AUTO" and "MANUAL" at any time during op- eration.

Room Temperature Mode: This setting, see below, will produce a room temperature of 70 degrees with the distribution blower at medium speed.

Manual Stove Temperature Mode

This setting will produce a large viewing fire without a distribution blower operating.

19

Page 19
Image 19
Harman Stove Company P61A manual Manual IGNITION/Operation