Installation

Installing

Place the stove on a noncombustible floor or on a floor protector that extends a minimum of 6 inches to the front, (measured from the glass) 6 inches to the sides and 1 inch to the rear of the hopper. It is also recommended that floor protection be installed under any horizontal venting and ex- tending 2 inches beyond the vent measurement. Material used for floor protection must be a minimum 3/8" of material rated at 0.84k per inch. Another method for calculating floor protec- tion is in R-value. Minimum permitted is 0.45 R. Example: 1" thickness of a material is rated at 0.52 R, which would meet the requirement.

Place the stove away from combustible walls at least as far as shown in Figures 3,4 and 5. Note the difference in side wall clearance with and without side shields.

Note that the clearances shown are minimum for safety but do not leave much room for access when cleaning or servicing.

Connect the power cord to a 120 V.A.C. 60Hz grounded receptacle. (A surge protector is recommended to protect the circuit board.) Also be sure that the polarity of the outlet that the stove is plugged into is correct.

Prior to installing the flue pipe, connect a draft meter. (The draft meter must have a minimum range of 0-.5.) Record the first reading. Connect flue pipe to stove and be sure all doors and windows in the home are closed. Record the second draft reading_______. If the second reading is more than .05"

lower than the first reading, check for possible restrictions or the need for outside air (see page 9). For more information on the draft test procedure, refer to Page 21.

Mobile Home Installation

When installing this unit in a mobile home, several require- ments must be followed:

1.The unit must be bolted to the floor. This can be done with 1/4" lag screws through the 2 holes in the base plate.

2.The unit must also be connected to outside air. See page

3.Floor protection and clearances must be followed as shown.

4.Unit must be grounded to the metal frame of the mobile home.

CAUTION: This appliance must be vented to the outside.

WARNING

the structural integrity of the

manufactured home floor,wall, and

ceiling/roof must be maintained.

WARNING

Mobile/Manufactured Home

Standards Do Not Allow

Installation In Rooms Designated

For Sleeping.

9" or 13"

 

 

 

 

9" or 13"

 

9" With Side Shields

Fig. 3

13" Without Side Shields

Fig. 4

Floor Protection must meet a minimum 2.24k value or lower. (The lower the k value, the better the protection.)

18"

Fig. 5

Fig. 6

P61A Pellet Stove 7

Page 7
Image 7
Harman Stove Company P61A manual Installing, Mobile Home Installation