Venting

12" min.

Storm collar

 

 

Flashing

3" min.

 

3" min.

3" min.

 

PL vent manufacturer's firestop spacer and support

No insulation or other combustible m a t e r i a l s a r e a l l o w e d w i t h i n 3" of the pellet vent pipe. Unless specified by the pipe manufacturer

(See Page 7 for corner installation clearances)

3" min.

Fig. 14

Minimum flue vent configuration

It is recommended that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure.

above ground level

#8 Installing through the ceiling

Through the ceiling vent, follow PL vent manufacturers recommendations when using wall and ceiling pass through. Note: Do not place joints within wall pass-throughs.

Fig. 15

18" Min.

12" min. wall to outlet

36" min clearance to any combustible material

Fig. 16

14P61A Pellet Stove

Page 14
Image 14
Harman Stove Company P61A manual Minimum flue vent configuration, #8 Installing through the ceiling