INSTALLATION
PERMANENT SURFACE MOUNT
Tubular Stand Mounting
Tubular stand mounting permanently attaches the unit to a countertop or serving table. All wiring may be concealed within the tubular stand.
Tubular stands are available in
NOTE: Tubular stands are not field
NOTE: If wiring is to be concealed, a 1" (25 mm) diameter hole must be provided in the mounting surface, centered under the leg flange nearest the electrical wiring hookup.
1.Position the unit
2.Units for this application are supplied with the conduit attached. Conduit should not be removed.
3.If applicable, route flexible conduit through the leg opening. Pull the leg up to the underside of the warmer. (See Figure 15.)
4.Secure legs to warmer using screws supplied.
5.If applicable, route the flexible conduit through opening in countertop.
6.Secure the legs to the mounting surface.
NOTE: The adjustable legs can be raised or lowered by turning the locking set screw counterclockwise one turn with an allen wrench, and then raising or lowering the unit to the desired height and retightening the screw. Do not loosen the screw more than necessary.
NOTE: Two pairs of legs will be needed for mounting dual units.
Covers
Locking
Screw
Adjustable
Leg
Flexible Conduit
Figure 15. Tubular Stand Mounting
Form No. | 14 |