1.27 | MAINTENANCE | 1.27 |
|
|
|
DUAL ELEMENT AIR CLEANER SERVICE
Refer to the Maintenance Schedule at the end of this section and ensure that the recommendations are followed. More frequent service is required when operating in adverse con- ditions.
- Gain access to the
4
by loosening screw (1) and tilting cover (2).
-To service the
-Clean the cartridge by tapping gently on a flat sur- face. If very dirty, replace or wash in a solution of
-After servicing, install the
5
1.Screw
2.Tilting Cover
3.Cartridge
4.
5.Base Cover
SPARK PLUG SERVICE
Use only Briggs & Stratton spark tester (1) to check for a spark as shown in the diagram.
Replace the spark plug every 100 hours or every season, which ever occurs first. A spark plug wrench is available from any authorised Briggs & Stratton service dealer.
The spark plug gap (2) should be checked with a feeler gauge and set at 0.76mm (0.030”).
485101MT210999A