Hearth and Home Technologies 6000GCF-IPI Top Vent - Vertical Termination - continued, Two Elbows

Models: 6000GCF-IPIL 6000GCF-IPI

1 61
Download 61 pages 49.31 Kb
Page 27
Image 27
Top Vent - Vertical Termination - (continued)

Top Vent - Vertical Termination - (continued)

Two Elbows

V2

 

V1

H1 Maximum

V2

V1 + V2

Minimum

6 in.

152 mm

3 ft

914 mm

*

*

 

*

 

 

 

 

 

 

 

 

1 ft

305 mm

3 ft

914 mm

*

*

 

*

2 ft

607 mm

6 ft

1.8 m

*

*

 

*

4 ft

1.2 m

12 ft

3.7 m

*

*

 

*

 

 

 

 

 

 

 

 

V1 + V2 + H1 = 50 ft (15.2 m) Max.

*No specific restrictions on this value EXCEPT

V1 + V2 + H1 cannot exceed 50 ft (15.2 m)

V1 = 6 inches (152 mm) Min.

H1

Figure 7.11

V1

Three Elbows

V2

 

V1

 

H1+ H2

V2

V1+ V2 Minimum

H1+ H2 Maximum

6 in.

152 mm

3 ft

 

914 mm

*

*

*

3 ft

914 mm

 

 

 

 

 

 

 

 

 

 

1 ft

305 mm

3 ft

 

914 mm

*

*

*

3 ft

914 mm

 

 

 

 

 

 

 

 

 

 

2 ft

610 mm

6 ft

 

1.8 m

*

*

*

6 ft

1.8 m

4 ft

1.2 m

12 ft

 

3.7 m

*

*

*

12 ft

3.7 m

H1 + H2 = 17 ft (5.2 m) Maximum

V1 + V2 + H1 + H2 = 50 ft (15.2 m) Maximum

V1 = 6 inches (152 mm) Minimum

H1

H2

V1

 

 

INSTALLED

 

HORIZONTALLY

Figure 7.12

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. H • 11/08

27

Page 27
Image 27
Hearth and Home Technologies 6000GCF-IPI Top Vent - Vertical Termination - continued, Two Elbows, Three Elbows, H1 Maximum